Hybrid Inverter

Technical Overview

IGrid Hybrid Inverter with Energy Storage

IGrid Hybrid Inverter with Energy Storage

  • MODEL PHASE 1-phase in / 1-phase out
  • RATED OUTPUT POWER 2000 W 3000 W 3000 W
  • MAXIMUM CHARGING POWER 1200 W 1200 W 1200 W
  • GRID-TIE OPERATION PV INPUT (DC) Maximum PV Input Power 2250W 3200W 4500W
  • Nominal DC Voltage / Maximum DC Voltage 300 VDC / 350 VDC 360 VDC / 500 VDC
  • Start-up Voltage / Initial Feeding Voltage 80 VDC / 120 VDC 116 VDC / 150 VDC
  • MPP Voltage Range 9’&a9’& 9’&a9’& Number of MPP Trackers
  • Maximum Input Current [$ [$ [$
  • GRID OUTPUT (AC) Nominal Output Voltage 101/110/120/127 VAC 208/220/230/240 VAC Output Voltage Range 88 – 127 VAC* 184 – 264.5 VAC*
  • Nominal Output Current 18 A 13 A 13 A Power Factor > 0.99
  • EFFICIENCY 95% 96% 96% 94% 95% 95%
  • OFF-GRID OPERATION AC INPUT AC Start-up Voltage/Auto Restart Voltage 60 – 70 VAC / 85 VAC 120 – 140 VAC / 180 VAC 120 – 140 VAC / 180 VAC
  • Acceptable Input Voltage Range 80 – 130 VAC 170 – 280 VAC 170 – 280 VAC
  • Maximum AC Input Current 30 A PV INPUT (DC) Maximum DC Voltage 350 VDC 500 VDC
  • MPP Voltage Range 150 VDC ~ 320 VDC 250 VDC ~ 450 VDC
  • Number of MPP Trackers / Maximum Input Current 1 / 1 x 15 A 1 / 1 x 13 A 1 / 1 x 18 A
  • BATTERY MODE OUTPUT (AC) Nominal Output Voltage 101/110/120/127 VAC 202/208/220/230/240 VAC
  • Output Waveform Pure Sinewave 90% 93% 93%
  • HYBRID OPERATION PV INPUT (DC) Nominal DC Voltage / Maximum DC Voltage 300 VDC / 350 VDC 360 VDC / 500 VDC
  • Start-up Voltage / Initial Feeding Voltage 80 VDC / 120 VDC 116 VDC / 150 VDC
  • MPP Voltage Range 150 VDC ~ 320 VDC 250 VDC ~ 450 VDC
  • Number of MPP Trackers /
  • Maximum Input Current 1 / 1 x 15 A 1 / 1 x 13 A 1 / 1 x 18 A
  • GRID OUTPUT (AC) Nominal Output Voltage 101/110/120/127 VAC 202/208/220/230/240 VAC
  • Output Voltage Range 88-127 VAC* 184 – 264.5 VAC*
  • Nominal Output Current 18 A 13 A 13 A
  • AC INPUT AC Start-up Voltage / Auto Restart Voltage 60 – 70 VAC / 85 VAC 120 – 140 VAC / 180 VAC 120 – 140 VAC / 180 VAC
  • Acceptable Input Voltage Range 80 – 130 VAC 170 – 280 VAC 170 – 280 VAC
  • Maximum AC Input Current 30 A
  • BATTERY MODE OUTPUT (AC) Nominal Output Voltage 101/110/120/127 VAC 202/208/220/230/240 VAC 90% 93% 93%
  • BATTERY & CHARGER Nominal DC Voltage 48 VDC
  • Maximum Charging Current 25A
  • GENERAL PHYSICAL Dimension, D X W X H (mm) 107 x 438 x 480
  • Net Weight (kgs) 15.5
  • INTERFACE Communication Port 5686%
  • Intelligent Slot Optional SNMP, Modbus, and AS-400 cards available
  • ENVIRONMENT Humidity 0 ~ 90% RH (No condensing)
  • Operating Temperature 0 to 40°C 0 to 40°C Altitude 0 ~ 1000 m**
  • **Power derating 1% every 100 m when altitude is over 1000m. ice.